Key result
An ultra-low power 36-nW electrocardiogram anomaly detector achieved a detection accuracy of 90.6% to 91.3% for identifying three different ECG anomalies on the MIT-BIH arrhythmia database.
Why the study?
Continuous cardiac monitoring requires an always-on electrocardiogram anomaly detector operating with ultra-low power consumption.
The proposed ultra-low power ECG anomaly detector achieves high accuracy for arrhythmia detection while consuming only 36 nW, making it highly suitable for always-on continuous cardiac monitoring.
May enable always-on ECG monitoring without high-resolution ADC; leaves open clinical validation in patients.
An always-on electrocardiogram (ECG) anomaly detector (EAD) with ultra-low power (ULP) consumption is proposed for continuous cardiac monitoring applications. The detector is featured with a 1.5-bit non-feedback delta quantizer (DQ) based feature extractor, followed by a multiplier-less convolutional neural network (CNN) engine, which eliminates the traditional high-resolution analog-to-digital converter (ADC) in conventional signal processing systems. The DQ uses a computing-in-capacitor (CIC) subtractor to quantize the sample-to-sample difference of ECG signal into 1.5-bit ternary codes, which is insensitive to low-frequency baseline wandering. The subsequent event-driven classifier is composed of a low-complexity coarse detector and a systolic-array-based CNN engine for ECG anomaly detection. The DQ and the digital CNN are fabricated in 65-nm and 180-nm CMOS technology, respectively, and the two chips are integrated on board through wire bonding. The measured detection accuracy is 90.6% ∼ 91.3% when tested on the MIT-BIH arrhythmia database, identifying three different ECG anomalies. Operating at 1 V and 1.4 V power supplies for the DQ and the digital CNN, respectively, the measured long-term average power consumption of the core circuits is 36 nW, which makes the detector among those state-of-the-art always-on cardiac anomaly detection devices with the lowest power consumption.
No takes yet. Share an insight, caveat, or question.
Pu et al. (2024) studied Cardiac anomalies / Arrhythmia. 36-nW Electrocardiogram Anomaly Detector was evaluated on Detection accuracy on the MIT-BIH arrhythmia database. An ultra-low power 36-nW electrocardiogram anomaly detector achieved a detection accuracy of 90.6% to 91.3% for identifying three different ECG anomalies on the MIT-BIH arrhythmia database.