Key result
PPG-based smart devices show insufficient evidence to reliably detect arterial hypertension.
Why the study?
It is important to diagnose arterial hypertension early and constantly monitor blood pressure, but guidance on the diagnostic accuracy of smart devices with photoplethysmography is needed.
Does photoplethysmography technology in smart devices accurately detect arterial hypertension compared to standard sphygmomanometers?
Systematic Review (n=643)
Does photoplethysmography technology in smart devices accurately detect arterial hypertension compared to standard sphygmomanometers?
Current smart devices utilizing PPG technology lack adequate validation and high-quality evidence to be recommended as reliable tools for clinical screening or early diagnosis of arterial hypertension.
Answers are grounded in this paper and cite their sources.
PPG smart devices lack support for hypertension detection in practice; leaves open the need for larger, unbiased validation studies.
Background: According to the World Health Organisation (WHO), 1 in 4 men and 1 in 5 women have arterial hypertension (AH). It is important to diagnose AH early and constantly monitor blood pressure (BP). We assess the diagnostic accuracy of AH detection using smart devices with photoplethysmography (PPG) and seek to provide guidance from current evidence to clinicians about the value and limitations of their potential use to early diagnose this chronic disease. Material and methods: This systematic review of Medline, Google Scholar, and PubMed databases was conducted according to the PRISMA guidelines. All publications examining any type of AH detection using PPG in smart devices were evaluated. Study quality was assessed using the QUADAS-2 risk of bias tool. Results: The search strategy identified a total of 705 publications, of which 9 studies were included in the systematic review. Of the 9 studies included, 2 used Samsung Galaxy smartphones, and 7 used wearable watch-like devices. A sphygmomanometer was used as a reference standard in all studies. Conclusion: The current evidence base consists of small, biased, and low-quality studies which are insufficient to advise clinicians on the true value of PPG devices for AH detection. Further research is required with reference standards, standardized validation, and transparent algorithms for PPG technology to be used as a valid tool for early AH diagnosis.
No takes yet. Share an insight, caveat, or question.
Andriekutė et al. (2023) conducted a systematic review in Arterial Hypertension (n=643). Photoplethysmography (PPG) in smart devices vs. Cuff-based sphygmomanometer was evaluated on Diagnostic accuracy for arterial hypertension detection. Current evidence from small, biased studies is insufficient to demonstrate the clinical applicability of smart devices using photoplethysmography for the accurate detection of arterial hypertension.
Synapse has enriched 10 related papers. Consider them for comparative context: