Answers are grounded in this paper and cite their sources.
Background Keratorefractive lenticule extraction (KLEx) commonly relies on empirical nomogram adjustments to improve refractive accuracy; however, astigmatism correction remains suboptimal. VISULYZE (Carl Zeiss Meditec AG) enables data-driven nomogram optimization, but its differential effectiveness across astigmatism severities has not been fully characterized. This study compared VISULYZE-assisted nomogram optimization with empirical nomogram adjustment for spherical and astigmatic correction, using stratified vector analysis to quantify gains in precision. Methods This retrospective case-control study included 206 eyes that underwent KLEx between December 2023 and July 2024 and completed a minimum 3-month follow-up. Eyes were assigned to either VISULYZE-assisted nomogram optimization (VISULYZE group, n = 99) or conventional empirical adjustment with a 10% spherical power increment (control group, n = 107). Stratified analyses were performed for low-to-moderate astigmatism (< 2.00 D; 57 vs. 62 eyes) and high astigmatism (≥2.00 D; 42 vs. 45 eyes). Primary outcomes included uncorrected distance visual acuity (UDVA), best-corrected distance visual acuity (BCVA), spherical equivalent (SE) accuracy, and residual astigmatism. Astigmatism vector analysis was performed using the Alpins method, including target-induced astigmatism (TIA), surgically induced astigmatism (SIA), difference vector (DV), and correction index (CI). Two-way analysis of variance was used to test interaction effects between nomogram type and astigmatism severity. Results At 3 months, 100% of eyes in the VISULYZE group achieved a UDVA of 20/20 or better, compared with 98% of control eyes; furthermore, 87% of the VISULYZE group vs. 73% of the control group achieved 20/16 or better ( P = 0.045). SE within ±0.50 D was achieved in 100% of VISULYZE eyes and 94.4% of control eyes ( P = 0.017). Residual astigmatism of 0.50 D or less was observed in 99% vs. 93.5% of eyes, respectively ( P = 0.042). Stratified analysis showed consistent benefits: both the low-to-moderate and high astigmatism subgroups demonstrated significantly better SE accuracy and lower residual astigmatism with VISULYZE (both P < 0.05). Interaction analysis (nomogram type × astigmatism severity) showed no significant effect on any primary outcome (all P > 0.05), indicating consistent VISULYZE-associated benefits across strata. Vector analysis showed significantly smaller DV values in VISULYZE eyes across both strata (0.00 vs. 0.25 D, P < 0.001; the TIA-SIA correlation was stronger in low-to-moderate astigmatism (R 2 = 0.9798 vs. 0.9363). Efficacy and safety indices did not differ significantly between groups. Conclusion VISULYZE-assisted nomogram optimization improved the accuracy of both spherical and astigmatic correction in KLEx, with consistent benefits across astigmatism severities. This data-driven, iterative refinement paradigm may standardize nomogram development and may be particularly valuable for less experienced surgeons transitioning from empirical adjustment to evidence-based, dynamically optimized surgical planning.
No takes yet. Share an insight, caveat, or question.
Liao et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: