Why the study?
Arrhythmias are increasing worldwide, making efficient training of electrophysiologists crucial, but dedicated simulators based on individual patient anatomy do not yet exist.
Does training in a novel advanced augmented reality-based simulator improve catheter steering skills for right atrial flutter ablation among novice and experienced electrophysiologists?
Does training in a novel advanced augmented reality-based simulator improve catheter steering skills for right atrial flutter ablation among novice and experienced electrophysiologists?
AAR-based simulator training using patient-specific MRI heart models allows non-experienced cardiologists to rapidly acquire catheter steering efficacy and safety comparable to experienced electrophysiologists.
May aid EP training; leaves open whether it improves real-world ablation outcomes.
Background Arrhythmias are rising worldwide due to population aging. Efficient ablation training of next generation electrophysiologists (EPs) is crucial. Dedicated simulators for EP training based on individual patient anatomy do not exist yet. Objective To assess the potential training effects of a novel advanced augmented reality (AAR)-based simulator for ablations. Methods An AAR-based simulator (Adis-SA, Switzerland) tracks the movements of a physical ablation catheter (Imricor, Burnsville, USA) in real-time within a completely virtual 3D-heart generated from cardiac MR examinations. Experienced EPs (n=4) and non-EP cardiologists (n=5) were trained in catheter steering skills. They performed 5 baseline right atrial flutter ablations (RA-FlAbl) in 5 different hearts, another 15 RA-FlAbl for training, and again 5 RA-FlAbl in the 5 baseline hearts. Efficacy (procedure time/catheter trajectory) and safety (high-force wall contacts, >50g) were recorded for coronary sinus (CS) cannulation and cavo-tricuspid isthmus ablations. Results 224 RA-FlAbl were performed. The training effect was evaluated using the 5 baseline and 5 post-training RA-FlAbl (43 pairs, 4 drop-outs). Before training, non-EPs had 2.6-times longer procedural time and catheter trajectories than EPs (each p<0.001, post-training: each ns) and 2.0-times more high-force wall contacts (p<0.04; post-training: ns). EPs also demonstrated modest improvements in ablation efficacy (p<0.003), but not for the simpler task of CS cannulation. Conclusions This feasibility study shows that training by means of an augmented reality-based simulator improves both the efficacy and safety of catheter steering skills for RA-FlAbl of EP trainees. After the training, they obtained a comparable efficacy and safety profile as experienced EPs.
No takes yet. Share an insight, caveat, or question.
Bacha et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: