Our work shows, through measurements on polypropylene films, the validity of surface potential measurements as a technique for dielectric properties analysis. We propose a representation of the decay and potential return curves that separates different components of dielectric response, by using tdv/dt vs log t plots. Using this transformation, and varying some experimental conditions we have identified different contributions to the potential decay. From our experimental observations we suggest a qualitative interpretation of the initial seconds of potential decay for negative corona charged samples that uses a model controlled by surface trap emission and charge exchanges between corona discharge and the insulator surface.
No takes yet. Share an insight, caveat, or question.
Llovera et al. (2004) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: