This is the authors' abstract. We don't add key points for this paper.
An on-line microwave-assisted decomposition procedure for the determination of lead in fish is proposed. 300 µL slurry and 400 µL of a 6 mol L-1 HNO3 solution were simultaneously injected, and the mixture was positioned inside a microwave oven. The decomposed sample inside the flushing solution was collected in the autosampler cup of a graphite furnace. The proposed procedure covered the 2.5 to 25 µg L-1 Pb range and presented a detection limit of 0.72 µg L-1 Pb. Precision expressed as RSD, was 10.5% (n = 20) for repeatability and 14.3% (n = 10) for reproducibility. Accuracy was assessed using standard reference material, and also by comparing the results to a nitric-perchloric decomposition procedure.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Arruda et al. (1997) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: