A compression-type metal hydride heat pump system has been constructed which utilizes the exothermic and endothermic characteristics of hydrogen storage alloy during its absorbing and desorbing reaction with hydrogen. The system is composed of two identical heat exchanger units, a hydrogen compressor, a cooling/heating fluid circulating system, and a control unit. Four effects on the system performance were examined: (1) hydrogen mass in the system, (2) fluid mass in the reservoir, (3) switch-cycle timing, (4) flow rate of the fluid. Under the optimal parameters, the output of the system was 1.65kW and the coefficient of performance (COP) was 3.7