Key result
Post-thrombectomy flat-panel CT shows high interrater reliability but fails to reliably match conventional CT for hemorrhage.
Cross-Sectional (n=26)
Blinded evaluators
Answers are grounded in this paper and cite their sources.
Reveals high interrater reliability of immediate flat-panel detector CT for detecting intracranial hemorrhage after mechanical thrombectomy, indicating its potential to expedite postprocedural care.
BACKGROUND AND PURPOSE: The risk of symptomatic intracranial hemorrhage (ICH) approaches 5% despite mechanical thrombectomy (MT) efficacy for ischemic stroke secondary to large vessel occlusion. Flat-panel detector CT (FDCT) imaging with Syngo Dyna CT imaging (Siemens Medical Solutions, Malvern, PA) can be used immediately following MT to detect ICH. PURPOSE: To evaluate the accuracy and reliability of FDCT imaging with Dyna CT compared to conventional post-MT CT and MRI. METHODS: Head FDCT (20 second, 70 kV) was performed immediately following MT on 26 consecutive patients; postprocedural CT or MRI was obtained ∼24 hours later. Two blinded, independent neuroradiologists evaluated all imaging, identifying ICH, stroke, and presence of subarachnoid contrast. Cohen's κ statistic was used to assess interrater agreement for each imaging outcome and compared the FDCT to conventional imaging. RESULTS: FDCT for ICH demonstrated a strong degree of interrater reliability (κ = 0.896; 95% confidence interval [CI], 0.734-1.057). Negligible reliability was seen for ischemia determination on immediate post-MT FDCT (κ = 0.149; 95% CI, -0.243 to 0.541). ICH evaluation between FDCT and post-MT conventional CT revealed modest interrater reliability (κ = 0.432; 95% CI, -0.100 to 0.965), which did not reach statistical significance. There was no substantive reliability in the evaluation of ICH between FDCT and post-MT MRI (κ = 0.118, 95% CI, -0.345 to 0.580). CONCLUSION: FDCT, such as Dyna CT, immediately post-MT is a promising tool that can expedite the detection of ICH with a high degree of reliability, although the detection of ischemic parenchymal changes is limited.
No takes yet. Share an insight, caveat, or question.
Inoa et al. (2023) conducted a cross-sectional in Ischemic stroke secondary to large vessel occlusion (n=26). Flat-panel detector CT (FDCT) vs. Conventional post-MT CT and MRI was evaluated on Agreement between FDCT and post-MT conventional CT for intracranial hemorrhage detection (κ 0.432, 95% CI -0.100 to 0.965). Flat-panel detector CT immediately following mechanical thrombectomy showed strong interrater reliability for ICH but modest, non-significant agreement with conventional CT.
Synapse has enriched 10 related papers. Consider them for comparative context: