Why the study?
Does systolic flow displacement assessed by 2D PC-MRI predict future ascending aortic growth in adult patients with bicuspid aortic valves?
Does systolic flow displacement assessed by 2D PC-MRI predict future ascending aortic growth in adult patients with bicuspid aortic valves?
Systolic flow displacement ≥0.2 on conventional 2D PC-MRI identifies patients with bicuspid aortic valves at risk for accelerated ascending aortic growth, offering better risk stratification than vessel diameter alone.
OBJECTIVES: Altered systolic blood flow in the ascending aorta has been correlated with increased aortic growth in patients with bicuspid aortic valves (BAVs). We used conventional, 2-dimensional (2D) phase contrast magnetic resonance imaging (PC-MRI) to assess the relationship between altered flow and future growth in patients with BAV. MATERIALS AND METHODS: Aortic MRI data were reviewed for 17 adult patients with BAV with right-left leaflet fusion undergoing surveillance imaging who had 2D PC-MRI through their ascending aortas on an initial study, follow-up studies more than 1 year later, and an initial maximum aortic diameter of less than 4.5 cm. Diameters were measured at standard levels by 2 blinded reviewers. Normalized systolic flow displacement was calculated at peak systole from the PC-MRI data, and correlation with the interval aortic growth was performed, with adjustment for clinical/demographic factors. RESULTS: The average follow-up interval was 2.9 ± 1.3 years. Systolic flow displacement at the initial study strongly correlated with ascending aortic growth rate (r = 0.71, P < 0.005) with moderate, non-significant correlation between initial diameter and growth (r = 0.45, P = 0.214). Aortic growth was 4 times faster in patients with initial flow displacement of 0.2 or greater (n = 9) compared with those (n = 8) with initial flow displacement less than 0.2 (0.8 ± 0.4 vs 0.2 ± 0.3 mm/y; P = 0.002). CONCLUSIONS: Systolic flow displacement calculated from conventional 2D PC-MRI in the ascending aorta correlates with future aortic growth in patients undergoing routine surveillance imaging for BAV. With a cutoff valve of 0.2, flow displacement may be used to identify a subset of patients likely to have elevated growth rates and may better risk-stratify patients with BAV for aortic disease progression than vessel diameter alone.
No takes yet. Share an insight, caveat, or question.
Burris et al. (2014) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: