Does arterial pulse power analysis accurately measure cardiac index compared to transpulmonary thermodilution in patients undergoing coronary artery bypass surgery?
Does arterial pulse power analysis accurately measure cardiac index compared to transpulmonary thermodilution in patients undergoing coronary artery bypass surgery?
Uncalibrated pulse power analysis is inaccurate for measuring cardiac output in CABG patients, and while calibration improves accuracy, it remains not consistently interchangeable with thermodilution.
Answers are grounded in this paper and cite their sources.
Uncalibrated pulse power analysis should not guide cardiac index decisions pre-CPB in CABG; leaves open calibration utility versus thermodilution.
INTRODUCTION: Uncalibrated arterial pulse power analysis has been recently introduced for continuous monitoring of cardiac index (CI). The aim of the present study was to compare the accuracy of arterial pulse power analysis with intermittent transpulmonary thermodilution (TPTD) before and after cardiopulmonary bypass (CPB). METHODS: Forty-two patients scheduled for elective coronary surgery were studied after induction of anaesthesia, before and after CPB respectively. Each patient was monitored with the pulse contour cardiac output (PiCCO) system, a central venous line and the recently introduced LiDCO monitoring system. Haemodynamic variables included measurement of CI derived by transpulmonary thermodilution (CITPTD) or CI derived by pulse power analysis (CIPP), before and after calibration (CIPPnon-cal., CIPPcal.). Percentage changes of CI (ΔCITPTD, ΔCIPPnon-cal./PPcal.) were calculated to analyse directional changes. RESULTS: Before CPB there was no significant correlation between CIPPnon-cal. and CITPTD (r2 = 0.04, P = 0.08) with a percentage error (PE) of 86%. Higher mean arterial pressure (MAP) values were significantly correlated with higher CIPPnon-cal. (r2 = 0.26, P < 0.0001). After CPB, CIPPcal. revealed a significant correlation compared with CITPTD (r2 = 0.77, P < 0.0001) with PE of 28%. Changes in CIPPcal. (ΔCIPPcal.) showed a correlation with changes in CITPTD (ΔCITPTD) only after CPB (r2 = 0.52, P = 0.005). CONCLUSIONS: Uncalibrated pulse power analysis was significantly influenced by MAP and was not able to reliably measure CI compared with TPTD. Calibration improved accuracy, but pulse power analysis was still not consistently interchangeable with TPTD. Only calibrated pulse power analysis was able to reliably track haemodynamic changes and trends.
No takes yet. Share an insight, caveat, or question.
Broch et al. (2011) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: