Why the study?
Does permanent pacemaker and ICD implantation without reversal of warfarin therapy increase complication rates in patients requiring device placement?
Does permanent pacemaker and ICD implantation without reversal of warfarin therapy increase complication rates in patients requiring device placement?
Performing pacemaker and ICD implantation without reversing warfarin therapy does not appear to increase periprocedural complication rates compared to patients with normal INR.
Answers are grounded in this paper and cite their sources.
May support omitting periprocedural anticoagulation reversal in device implantation; leaves open need for randomized confirmation.
The study evaluated all patients undergoing permanent pacemaker and ICD implantation over a 4-year period to determine if anticoagulated patients required normalization of coagulation factors in the periprocedural period. The study included 1,025 (597 men, 428 women, age 24-100 years, mean 72 years) consecutive patients who underwent device implantation using mostly a percutaneous subclavian approach. The procedures were performed without reversal of anticoagulation in 470 patients with INRs >or= 1.5 at the time of the procedure (mean INR 2.6 +/- 1.0, range 1.5-7.5). The complication rate in the anticoagulated group was similar to those in patients with a normal INR. Routine normalization of coagulation factors prior to pacemaker/ICD placement may not be necessary.
No takes yet. Share an insight, caveat, or question.
Giudici et al. (2004) studied this question.