Answers are grounded in this paper and cite their sources.
Flux weakening is an inevitable requirement in the operation of variable speed permanent magnet (PM) machines for high‐speed applications due to inverter voltage limits. A new winding switching technique is experimentally validated in this study that can extend the speed range of such PM machines. A drive topology is proposed that utilises two current regulated voltage source inverters to control the machine in a dual inverter fed configuration before transitioning into an open winding configuration after winding switching. The proposed drive topology extends the constant torque region of the machine and boosts its maximum output power capability. Complete experimental results are provided to demonstrate the effectiveness of the proposed machine drive system for continuous operation over the entire speed range.
No takes yet. Share an insight, caveat, or question.
Atiq et al. (2016) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: