Answers are grounded in this paper and cite their sources.
In this paper, an inductively coupled pulsed plasma source with an operating frequency of 29 kHz is described. Using a series resonance circuit with a load capacitance of 12 muF and large diameter (approximately 20 cm) induction coils surrounding a spherical discharge vessel, a discharge plasma was produced and investigated in a pressure range of 0.1 to 100 Pa. Pulsed coil currents reached a maximum value of 9.6 kA with current rise times of 1.8 kA/mus while achieving an energy coupling efficiency of 80% between the driving circuit and the plasma. Pulsed-power peak values reached more than 800 kW. Moreover, the spectroscopic diagnostic revealed a high fraction of ionized particles and an emission spectrum in the near UV domain. Electron densities reached peak values of 1021m-3. By using a fast camera system, the initiation of the discharge was investigated. The ignition of the discharge along an azimuthal path was documented, showing evidence of an entirely inductive plasma initiation without capacitive coupling.
No takes yet. Share an insight, caveat, or question.
Teske et al. (2008) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: