This paper describes the application of a parameter optimizing technique to determine numerical values for a circuit model of a squirrel-cage induction machine. The model includes the effects of magnetic saturation of the main and leakage flux paths and skin effect in the rotor bars. All parameters have been measured at different voltage levels up to the rated value to demonstrate the effect of magnetic saturation.