The WTC disaster provided an opportunity to look for ways to prevent morbidity among occupants of high-rise buildings during fires. This paper first describes the overall morbidity resulting from the explosion and fire, and second, presents the results of a case-control study carried out to identify risk factors for smoke-related morbidity. The main ones include: increased age, presence of a pre-existing cardio-pulmonary condition, entrapment in a lift and prolonged evacuation time. Study results point to the importance of the following safety systems during high-rise building fires: smoke-control systems with separate emergency power sources; lift-cars, lift-car position-monitoring systems, and lift-car communication systems with separate emergency power sources; two-way emergency communication systems on all floors and in stairwells; stairwells with emergency lighting and designed for the rapid egress of crowds; evacuation systems/equipment to assist in the evacuation of vulnerable people (elderly, infirm). Also important are evacuation plans that include regularly scheduled safety training and evacuation drills.
No takes yet. Share an insight, caveat, or question.
Quenemoen et al. (1996) studied this question.
Synapse has enriched one closely related paper. Consider it for comparative context: