Key result
Graded exercise increases pulmonary capillary blood flow ~2.3-fold from baseline via intrabreath gas absorption testing.
Why the study?
The practicality and normal reference responses of integrating single-breath measurements of carbon monoxide lung diffusion (DLCO) and noninvasive cardiac output (QC) into clinical graded exercise testing needed to be defined to detect impairment in patients with suspected pulmonary or pulmonary vascular disease despite normal resting values.
Does integrating single-breath gas absorption measurements of lung diffusion (DLCO) and non-invasive cardiac output (QC) into standard graded exercise testing provide reliable reference responses across progressive workloads in normal subjects?
Observational (n=20)
No
Does integrating single-breath gas absorption measurements of lung diffusion (DLCO) and non-invasive cardiac output (QC) into standard graded exercise testing provide reliable reference responses across progressive workloads in normal subjects?
Establishes normative clinical reference equations and feasibility for non-invasive single-breath cardiac output and lung diffusion measurements during routine incremental cardiopulmonary exercise testing.
Answers are grounded in this paper and cite their sources.
Supports single-breath DLCO and QC measurements during exercise in healthy subjects; leaves open clinical adoption pending validation.
Measurement of lung diffusion and cardiac output with a single breath gas absorption method during graded exercise testing: reference values for clinical testing.Objective: The evaluation of ventilation and gas exchange has become a standard part of clinical exercise testing.We sought to assess the practicality of integrating measurements of lung diffusion for carbon monoxide (D L CO) and noninvasive cardiac output (using pulmonary capillary blood flow Q C ) into our clinical graded exercise tests.Our objective was to define the responses in normal subjects so that impairment could be detected in patients suspected of having pulmonary or pulmonary vascular disease despite normal resting D L CO and Q C .We conducted incremental exercise tests on 20 normal volunteers at 6 levels of exercise ranging between rest and 75% of their measured maximum.The investigational method is based on absorption of CO (for D L CO) and acetylene (for Q C ) into the pulmonary circulation during a single slow exhalation.The subjects averaged 35 years of age with a maximum work capacity of 76% of predicted maximum. Results:The values increased linearly with workload (Q C in L/min = 3.5 + 6.5*VO 2 in L/min, and D L CO in ml/min/mmHg = 18.7 + 10.2*VO 2 in L/min).From baseline levels the Q C increased more than two-fold and the D L CO increased by 50%.The mean deviation of individual measurements from the patient's regressed response was 9.9% and 6.6% respectively. Conclusions:We found the procedure easy to include in our standard graded exercise protocol and the single breath technique readily performed.Normative values were obtained for measurements expressed as a percentage of individual maximum and as actual VO 2 .At a moderate level of exercise (VO 2 1.0 liter) the D L CO and Q C should increase at least 20% and 65% respectively above baseline.Since the response of Q c and D L CO to progressive exercise offers pathophysiological information of clinical interest, its application can now be characterized in patients with different disorders including those with normal resting Q c and D L CO.
No takes yet. Share an insight, caveat, or question.
Miller et al. (2009) conducted an observational in Normal healthy volunteers undergoing graded exercise testing (n=20). Intrabreath single breath gas absorption method during graded exercise testing vs. Resting baseline levels was evaluated on Pulmonary capillary blood flow (QC) and lung diffusion for carbon monoxide (DLCO) response from rest to 76% maximum exercise (95% CI 205%-277%, p=<0.05). Intrabreath gas absorption during graded exercise testing showed linear increases with workload, with pulmonary capillary blood flow increasing over two-fold and lung diffusion by 50% from baseline.
Synapse has enriched 10 related papers. Consider them for comparative context: