Answers are grounded in this paper and cite their sources.
Quality improvements and reduction of disease risk for low-resource shared sanitation facilities require cleanliness assessment approaches that are both rigorous and practical. Using Adenosine Triphosphate (ATP) bioluminescence testing, we assessed contamination on high-touch (HT) surfaces (inner door handles) at 32 shared toilet sites in Kisumu, Kenya. In public toilets, contamination was lowest after cleaning and disinfection (C&D) with 0.5% chlorine solution (adjusted difference in mean log 10 Relative Light Units per 100 cm 2 (aDiff): −1.61; CI: −2.43, −0.59), followed by C&D with 0.1% chlorine solution (aDiff: −1.16; CI: −1.77, −0.55). ATP levels were not associated with overall observable toilet cleanliness and had poor agreement with visually assessed HT surface cleanliness. Our findings demonstrate the utility of this field-feasible method for detecting the impact of recent C&D in low-resource shared toilets, a novel setting for ATP cleanliness testing, while also highlighting the importance of using effective C&D procedures and addressing HT surfaces within cleaning protocols.
No takes yet. Share an insight, caveat, or question.
Prentice‐Mott et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: