Why the study?
The study was conducted to evaluate a single-center experience with the novel balloon-expandable Myval Transcatheter Heart Valve system in TAVR procedures.
Does the Myval THV system provide safe and effective outcomes in patients undergoing TAVR?
Does the Myval THV system provide safe and effective outcomes in patients undergoing TAVR?
The Myval balloon-expandable THV demonstrates a favorable safety and efficacy profile with high technical success and low complication rates at 3 months in patients undergoing TAVR.
Myval THV shows early feasibility in TAVR; leaves open need for randomized comparisons before wider adoption.
Background and Aims Our objective is to report our single‐center experience with the novel balloon‐expandable Myval Transcatheter Heart Valve (THV) system in Transcatheter Aortic Valve Replacement (TAVR) procedures. Methods We conducted a retrospective study on a cohort of consecutive patients who underwent TAVR utilizing Myval THV from September 2021 to August 2023 at a tertiary care cardiac center. We collected baseline characteristics, pre‐ and post‐procedural echocardiographic findings, procedural details, in‐hospital outcomes, VARC‐3 technical success, and complications. Additionally, patients were followed up for 3 months concerning their clinical outcomes. Results The study population comprised 92 TAVR patients with a mean age of 76.8 ± 7.3 years, 66.3% were male, and the mean STS score was 5.9 ± 3.2%. The most common valve sizes used were 24.5 mm (30.4%), 23 mm (26.1%), and 27.5 mm (17.4%). Pre‐dilation was performed in 32 cases (34.8%), achieving a 93.5% technical success rate. In‐hospital mortality occurred in three patients (3.3%), which included one annulus rupture. Permanent pacemaker implantation was required in six patients (6.5%). Three patients (3.3%) exhibited 3+ paravalvular leakage demonstrated by angiography. The New York Heart Association (NYHA) functional class showed significant improvement from baseline to discharge ( p < 0.0001). At the 3‐month follow‐up, five patients encountered mortality (5.4), and three experienced an episode of stroke or transient ischemic attack (3.2%). Two other patients were hospitalized due to cardiovascular events during the 3‐month follow‐up. Conclusion The Myval THV shows a favorable safety and efficacy profile in TAVR, with low mortality and complications at 3 months.
No takes yet. Share an insight, caveat, or question.
Baay et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: