Answers are grounded in this paper and cite their sources.
Chemical mechanical polishing (CMP), as a widely used global smoothing technique, requires a high polishing rate and a low surface roughness. However, it is difficult to meet these requirements with single-step polishing. To obtain a perfect 4H-SiC wafer surface, we studied a two-step CMP 4H-SiC wafer using a-Al 2 O 3 -based slurry and nano-SiO 2 -based slurry. Before the two-step process was determined, the effect of concentration of KMnO 4 and pH on the polishing rate of 4H-SiC was first studied with Al 2 O 3 as the abrasive, and the maximum polishing rate of 1400 nm h −1 was determined under the condition of pH of 2.00 and KMnO 4 concentration of 6.5 wt% in the step. Furthermore, the effect of H 2 O 2 concentration on the polishing rate of 4H-SiC was investigated using SiO 2 as the abrasive and V 2 O 5 as the catalyst. It was determined that under the condition of V 2 O 5 concentration of 4 wt% and H 2 O 2 concentration of 10 wt%, the maximum polishing rate of the second step polishing was 150 nm h −1 , and a perfect surface was obtained, with a surface roughness of 0.066 nm. In addition, the in situ friction coefficients have used to characterize the two-step process. At the end, the CMP mechanisms of the above two slurry have been deduced and preliminarily demonstrated.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: