A sample preconcentration technique that exceeds a microfluidic device’s limited processing volume (up to microliters) is critical for real sample pretreatment applications. Here, we have developed a 3D-printed preconcentrator with a pillar structure (3DP 2 ) to enrich the biological samples up to hundreds of microliter scales (700 μL) within 20 min by utilizing ion concentration polarization (ICP). We designed three-dimensional ready-to-pick reservoirs serially connected with a pillar-structured channel to enable large-volume preconcentration by balancing the preconcentrating forces (depletion, electrophoretic, and electroosmotic force) generated by ICP. Using the I-t and I-V curves, we confirmed that ICP performance was enhanced due to a pillar structure’s suppression of the vortex. Finally, we preconcentrated bovine serum albumin (BSA) and micro ribonucleic acid-21 (miRNA-21) two-fold. Moreover, depending on their size and charge, these were concentrated at different locations and could be extracted easily using pipettes. We believe that this study provides a novel strategy for downstream applications.
No takes yet. Share an insight, caveat, or question.
Lee et al. (2022) studied this question.