Why the study?
Pulmonary valve stenosis has variable severity, and prenatal echocardiography has limited ability to predict the need for neonatal valvuloplasty.
Does a fetal echocardiographic score including 2D speckle-tracking predict the need for neonatal valvuloplasty in fetuses with isolated pulmonary valve stenosis?
Does a fetal echocardiographic score including 2D speckle-tracking predict the need for neonatal valvuloplasty in fetuses with isolated pulmonary valve stenosis?
A novel 4-point fetal echocardiographic score incorporating 2D speckle-tracking accurately predicts the need for early neonatal valvuloplasty in fetuses with isolated pulmonary valve stenosis.
Answers are grounded in this paper and cite their sources.
May aid perinatal planning in fetal PS; leaves open need for prospective validation before adoption.
INTRODUCTION: Pulmonary valve stenosis (PS) is a common congenital heart defect with variable severity. Prenatal echocardiography has limited ability to predict neonatal valvuloplasty. We aimed to evaluate the prediction accuracy of fetal echocardiography, including 2D speckle-tracking echocardiography (2D-STE). METHODS: A prospective cohort study including 24 cases of isolated PS (7 critical, 17 mild-moderate) and 48 gestational age-matched healthy controls was conducted at BCNatal. Cases were matched with 48 healthy controls adjusted by gestational age at echocardiography. Comprehensive fetal echocardiography and 2D-STE were performed for diagnosis. RESULTS: Median gestational age at echocardiography was 32.5 weeks (27.4-35.4). Half of the PS fetuses underwent valvuloplasty within the first month of life. PS fetuses showed impaired right ventricular function (reduced tricuspid annular plane systolic excursion, more pulsatile ductus venosus), with preserved left ventricular function. Four independent predictors were identified: ductus venosus pulsatility index ≥79th centile, right ventricular global longitudinal strain ≥-15.9%, reversed flow in the ductus arteriosus, and significant tricuspid regurgitation. When combined into a simple 4-point score, values ≥2 predicted valvuloplasty with 91.7% sensitivity and 100% specificity (AUC: 0.931). CONCLUSION: These findings suggest that a fetal echocardiographic score may accurately identify a fetus with PS needing early neonatal valvuloplasty, allowing improved perinatal management. Further validation studies are needed.
No takes yet. Share an insight, caveat, or question.
Nogué et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: