Why the study?
Does the tissue Doppler method provide interchangeable Tei index measurements compared to the pulsed-wave Doppler method in fetuses?
Population
147 fetuses that had a fetal echocardiogram and Tei index measured during a 2-year period
Comparison
Tissue Doppler method for measuring right and… vs Pulsed-wave Doppler method for measuring right…
Design
Cross-sectional
Authors
Loading...
TD and PD Tei indices should not be interchanged for fetal cardiac assessment; leaves open need for method-specific norms and validation.
Does the tissue Doppler method provide interchangeable Tei index measurements compared to the pulsed-wave Doppler method in fetuses?
Pulsed-wave Doppler and tissue Doppler methods yield poorly correlated Tei indices in fetuses and cannot be used interchangeably for assessing fetal cardiac function.
Acharya et al. (2008) studied this question.