Why the study?
Does intrapartum monitoring with STAN in breech presentation compared to vertex presentation show different electrocardiographic performance and neonatal outcomes?
Does intrapartum monitoring with STAN in breech presentation compared to vertex presentation show different electrocardiographic performance and neonatal outcomes?
STAN can be used for surveillance of breech presentations selected for vaginal delivery with acceptable neonatal outcomes, though ECG patterns during labor vary by fetal presentation.
Answers are grounded in this paper and cite their sources.
STAN remains feasible for selected breech labors with no mortality difference; extends observational data but requires randomized confirmation before wider adoption.
OBJECTIVE: To determine the electrocardiographic performance and neonatal outcome of pregnancies with breech presentation and planned vaginal delivery monitored with ST-waveform analysis (STAN). DESIGN: Prospective observational study. SETTING: University hospital, Norway; 2004-2008. POPULATION: Singleton pregnancies with a gestational age above 35 + 6 weeks, breech presentation, selected for vaginal delivery and monitored with STAN. METHODS: Common clinical guidelines for STAN monitoring were used. An experienced neonatologist graded the symptoms of neonatal encephalopathy. The outcome was compared with STAN-monitored high-risk deliveries in a vertex presentation (n = 5569) using logistic regression analysis. MAIN OUTCOME MEASURE: Frequency of ST events, indications of intervention for fetal distress, and neonatal morbidity and mortality. RESULTS: Breech presentation occurred in 750 of 23,219 (3.2%) deliveries, 625 (83%) of which were selected for vaginal delivery. Intrapartum monitoring by STAN was performed in 433 (69%). Compared with vertex presentations, fetuses in breech presentation had a lower risk of baseline T/QRS rise during labour [odds ratio (OR) = 0.7, 95% confidence interval (95% CI) = 0.7-0.9, P = 0.003] and a higher risk for intervention as a result of preterminal cardiotocogram (OR = 2.9, 95% CI = 1.6-5.9, P = 0.001). The risks of perinatal mortality (OR = 1.8, 95% CI = 0.2-15, P = 0.6), cord metabolic acidosis (OR = 0.8, 95% CI = 0.2-3.2, P = 0.7) and moderate or severe neonatal encephalopathy (OR = 1.8, 95% CI = 0.5-6.2, P = 0.3) did not differ significantly between breech and vertex deliveries. CONCLUSION: STAN can be used for the surveillance of breech presentations selected for vaginal delivery with an acceptable neonatal outcome. The electrocardiogram (ECG) pattern during labour varies with the fetal presentation.
No takes yet. Share an insight, caveat, or question.
Kessler et al. (2014) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: