The recommended specimen for measuring cyclosporine concentrations is whole blood anticoagulated with EDTA (1). Traditionally, these specimens have been collected in glass tubes. Because of safety issues, evacuated plastic tubes are now available for blood collection. However, because it is known that cyclosporine is adsorbed by some kinds of plastics (2), there is no guarantee that cyclosporine concentrations in specimens collected in plastic tubes will remain stable. Dasgupta et al. (3) examined the effect of plastic collection tubes on 13 therapeutic drugs. One of the drugs they examined was cyclosporine. However, no cyclosporine data were exhibited in their paper, and the stability was monitored for only 24 h. We wished to undertake a more complete study. Additionally, because some of our specimens are shipped to us from remote locations, we sought to examine the stability of cyclosporine in plastic tubes for longer than 1 day. Sterile 3-mL glass and plastic evacuated blood collection tubes (Vacutainer® and Vacutainer PLUS, respectively) with EDTA anticoagulant were obtained from Becton Dickinson Vacutainer Systems. Specimens in glass and plastic tubes were collected simultaneously from renal transplant patients receiving cyclosporine to prevent rejection. Specimens were collected only from patients whose physicians had requested cyclosporine measurements. Tubes were stored at 4 °C or room temperature after collection and between analyses. Specimens were analyzed for cyclosporine concentrations within 24 h of collection (day 0), and 1, 4, and 7 days thereafter (days 1, 4 and 7, respectively). Specimens were mixed by rocking for at least 10 min at room temperature before analysis. Cyclosporine concentrations were measured by fluorescence polarization immunoassay on an Abbott TDx using the Abbott Cyclosporine Monoclonal Whole Blood assay kit (Abbott Laboratories). Assays were performed according to the manufacturer’s procedure. In the first experiment, 14 specimens from 12 patients were stored at 4 °C and analyzed over 7 days. Cyclosporine concentrations ranged from 91 to 611 μg/L (glass tubes, day 0). For most samples, the value in the plastic tube was slightly higher than the value from the glass tube (individual data not shown). The paired t-tests on each day were statistically significant (P <0.05). The average concentrations for these 14 specimens on each day for the two specimen containers (glass vs plastic) are shown in Table 1 . As can be seen, the means of the concentrations from the specimens collected in plastic tubes were slightly higher than the specimens collected in glass tubes, al-though the means were not statistically different (unpaired t-tests). The average percentage difference between the plastic and glass tubes ranged from 2.4% on day 0 to 4.3% on day 4 and did not appear to be time-dependent. All of the differences for individual pairs of tubes were <10%, except on 2 days for one set of specimens, where the differences were 23% and 16%. These may have been attributable to inadequate mixing, because Dasgupta et al. found similar differences in inadequately mixed tubes. The average concentrations varied only slightly from day to day. Cyclosporine concentrations (μg/L) in glass and plastic tubes. Cyclosporine concentrations (μg/L) in glass and plastic tubes. In the second experiment, 10 samples from 10 patients were stored at room temperature and analyzed at the same intervals as the previous experiment. Cyclosporine concentrations ranged from 151 to 662 μg/L. Because of questions concerning mixing in the previous experiment, the mixing step was standardized at 10 min of rocking. These data are also shown in Table 1 . The mean concentrations for the glass tubes were not statistically different from the mean concentrations for the plastic tubes on any day (unpaired t-tests). Two of the paired t-tests showed statistical significance. The average percentage difference between the glass and plastic tubes ranged from −1.0% to 2.7%. All of the differences for individual pairs of tubes were <10%, except on 1 day for one set of specimens from one patient, where the difference was 14%. Dasgupta et al. (3) considered differences of <10% acceptable. In addition, the Canadian Consensus Panel (4) considered an error of 30 μg/L at a concentration of 300 μg/L (10%) acceptable. Because the average of the differences from our study are well within these ranges, we consider the plastic tubes acceptable for collection of specimens for cyclosporine measurement. Furthermore, we found that cyclosporine concentrations are stable in plastic tubes over 7 days at 4 °C or at room temperature. The plastic collection tubes used in the first experiment were provided by Becton Dickinson Vacutainer Systems (Franklin Lakes, NJ). We thank Valerie Bush of Becton Dickinson for reviewing the data and analysis.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Faynor et al. (1998) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: