Key result
Maximal treadmill stress testing shows zero mortality, with ~63% of ischemic ST changes occurring painlessly.
Observational (n=4,028)
Answers are grounded in this paper and cite their sources.
Experience with a maximal treadmill stress testing procedure which is relatively safe, simple, and reproducible is reported. It has been used in normal persons and cardiac patients with ages ranging from 7 to 83 years. There have been no deaths in our total experience of 4,028 maximal capacity stress tests. Maximal capacity is predicted by the patient's peak predicted pulse rate. Sixty-three per cent of those with ischemic S-T segments did not experience pain of any type.
No takes yet. Share an insight, caveat, or question.
Ellestad et al. (1969) conducted an observational in Normal persons and cardiac patients (n=4,028). Maximal treadmill stress testing was evaluated on Deaths during testing. Maximal treadmill stress testing was safe with zero deaths across 4,028 tests, and 63% of individuals with ischemic S-T segments experienced no pain of any type.
Synapse has enriched 10 related papers. Consider them for comparative context: