Why the study?
Do baseline variables, such as left ventricular end-diastolic diameter, predict cardiac events during exercise therapy in stable heart failure patients?
Do baseline variables, such as left ventricular end-diastolic diameter, predict cardiac events during exercise therapy in stable heart failure patients?
In stable heart failure patients undergoing exercise training, a baseline LVEDD ≥ 65 mm is a strong predictor of cardiac events requiring interruption or withdrawal from the program, suggesting a need for careful monitoring in this subgroup.
Answers are grounded in this paper and cite their sources.
LVEDD ≥65 mm may identify HF patients needing closer monitoring during exercise training; leaves open whether it should guide enrollment or program design.
BACKGROUND: Exercise training (ET) is an emerging therapy for chronic heart failure, but the baseline patient characteristics for predicting cardiac events (CEs) during the course of ET remain unknown. METHODS AND RESULTS: Of the 111 stable heart failure patients who participated in a 3-month ET program, 6 withdrew from the program for cardiac reasons and 9 had transient interruptions in the program because of CEs. The baseline clinical characteristics of these 15 patients (CE group) and the remaining 96 patients (No-CE group) were compared. Compared with the No-CE group, the CE group had a significantly higher prevalence of pacemaker/implantable cardioverter-defibrillators, larger left ventricular end-diastolic diameter (LVEDDs), lower peak oxygen uptake, greater ventilation drive, and higher plasma brain natriuretic peptide concentration at baseline. Multivariate logistic regression analysis showed that a larger LVEDD was a significant predictor of the occurrence of a transient interruption to or permanent withdrawal from the ET program because of CEs. Receiver operating characteristic curve analysis demonstrated that an LVEDD > or = 65 mm had a sensitivity of 93% and specificity of 48% in predicting CEs. CONCLUSIONS: Patients with a large LVEDD (> or = 65 mm) at baseline should be monitored carefully during the course of an ET program.
No takes yet. Share an insight, caveat, or question.
Nishi et al. (2007) studied this question.