Randomized trial demonstrates automated lung injury classification in chest CT scans, indicating improved accuracy and interpretability.
This study developed and evaluated a hybrid deep learning framework for automated lung segmentation and multi-class severity classification in chest CT scans, addressing key methodological gaps including heterogeneous dataset labeling, pseudo-label bias in segmentation, limited interpretability of intensity thresholds, and unvalidated preprocessing effects. A dataset of 3,921 chest CT images from three geographically distinct sources (Iran, Bangladesh, Iraq) was harmonized into four severity classes (No Lesion, Mild, Moderate, Severe) through a structured expert annotation protocol (κ = 0.847) and augmented to 4,392 balanced samples. U-Net architectures with three CNN backbones (VGG16, ResNet50, Xception) were trained for lung segmentation with CLAHE preprocessing and evaluated against both morphological pseudo-labels and independently annotated expert ground truth. A novel Brightness Intensity Range (BIR) classifier analyzed pixels within the normalized intensity range [0.35, 0.70], corresponding to approximately − 450 to + 100 HU and encompassing ground-glass opacities and partial consolidation, using perimeter-to-area ratio thresholds for severity stratification. Hybrid classification pipelines combined CNN feature extraction with SVM, Gradient Boosting, and Logistic Regression classifiers. A controlled ablation study isolated the contribution of each preprocessing step. All models were evaluated using patient-level fivefold cross-validation to prevent data leakage between training and test partitions. The VGG16-based U-Net achieved 98.1% segmentation accuracy with a Dice coefficient of 0.927 against pseudo-labels and 0.921 ± 0.089 against expert annotations, confirming that pseudo-label training introduced no systematic bias. ResNet50 + GradientBoosting achieved the highest classification accuracy of 96.35 ± 0.82% with ROC-AUC exceeding 99% across all classes. The BIR-VGG16 model reached 94.8% accuracy with ROC-AUC values of 0.963 to 0.988. The ablation study identified normalization as the dominant preprocessing contributor (34.3% accuracy gain), followed by CLAHE (21.7%) and resizing (6.0%), mechanistically explaining the large performance gap between preprocessed and non-preprocessed conditions. Cross-dataset generalization yielded 93.78% accuracy on an independent cohort. The proposed framework demonstrates superior performance, methodological transparency, and clinical viability. The explicit HU-grounded BIR thresholds, expert-validated segmentation, and ablation-confirmed preprocessing rationale collectively enhance the generalizability of the approach for automated lung pathology assessment.
No takes yet. Share an insight, caveat, or question.
Behtaji et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: