Answers are grounded in this paper and cite their sources.
Mario A. Alpuche-Aviles opened a general discussion of the papers by Serge Lemay: The concentrations have to be very low and one worries about background issues and the effect of contaminants.Why do they have to be this low?Could these experiments be performed at higher concentrations?Serge Lemay replied: We would love to be able to work at higher concentrations!The concentration is currently set by the need to work under conditions where there is less than one molecule on average present inside the device.This is needed because the nite time resolution of femtoampere-level electronics leads to blurring of single-molecule signals if they overlap signicantly in time. 1 The device volume, in particular the channel width and height, are in turn mostly limited by our fabrication approach.While it would be possible to make shorter devices, the expected residence times would be reduced, which would in turn make the experiment more challenging.
No takes yet. Share an insight, caveat, or question.
Gooding et al. (2016) studied this question.