Why the study?
Does SAPIEN transcatheter pulmonary valve placement improve echocardiographic parameters of pulmonary valve and right ventricular function?
Does SAPIEN transcatheter pulmonary valve placement improve echocardiographic parameters of pulmonary valve and right ventricular function?
SAPIEN transcatheter pulmonary valve implantation significantly improves pulmonary insufficiency, stenosis, and right ventricular size at 6 months, though RV systolic function remains unchanged.
Supports short-term echocardiographic improvement after SAPIEN TPV; leaves open randomized confirmation of durability and outcomes.
OBJECTIVES: To evaluate echocardiographic changes after SAPIEN valve implantation in the pulmonary position. BACKGROUND: The feasibility of the SAPIEN transcatheter pulmonary valve (TPV) has recently been demonstrated. We evaluated changes in pulmonary valve function and the right ventricle after SAPIEN TPV placement. METHODS: We evaluated echocardiograms at baseline, discharge, 1 and 6 months after TPV placement in 33 patients from 4 centers. Pulmonary insufficiency severity was graded 0-4. TPV peak and mean gradients were measured. Right ventricular (RV) size and function were quantified using routine measures derived from color, spectral, and tissue Doppler indices and two-dimensional echocardiography. RESULTS: At baseline, 94% patients demonstrated pulmonary insufficiency grade 2-4. This decreased to 12% patients at 6 months (P < 0.01). TPV peak (P < 0.01) and mean gradient (P < 0.01) decreased. RV end-diastolic area indexed to body surface area (BSA) (P < 0.01), Tricuspid regurgitation (TR) gradient (P < 0.01), and the ratio of TR jet area to BSA (P < 0.01) decreased. Tricuspid inflow peak E:A, tissue Doppler imaging (TDI): septal E' and A', TDI: tricuspid A' improved between baseline and discharge, but trended back to baseline by 6-month follow-up. Tricuspid valve annulus z-score, RV area change, tricuspid annular plane systolic excursion (TAPSE), RV dP/dt, tricuspid E:E', and TDI: tricuspid annulus E' showed no change. CONCLUSION: Improvements in pulmonary insufficiency and stenosis, RV size, and TR gradient and severity are seen after SAPIEN TPV placement. Selected indices of RV diastolic function improve immediately after TPV implantation, but return to baseline by 6 months. RV systolic function is unchanged.
No takes yet. Share an insight, caveat, or question.
Chowdhury et al. (2013) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: