Tissue Doppler-derived E(m) is a reliable parameter of diastolic function that correlates with diabetes compensation (HbA1c) and duration in patients with type 2 diabetes.
Answers are grounded in this paper and cite their sources.
E(m) may aid diastolic assessment in T2DM; supports glycemic correlations yet leaves open prognostic utility.
This study assessed the impact of tissue Doppler derived myocardial early diastolic relaxation velocity (E(m)) on the other parameters of diastolic function (preload dependent transmitral early diastolic velocity [E], tissue Doppler derived myocardial late diastolic velocity [A(m)], preload dependent transmitral late diastolic velocity [A]) and evaluated the correlation of these parameters with selected clinical variables in type 2 diabetic patients. Using tissue Doppler echocardiography, 82 type 2 diabetic patients were evaluated, divided into two equal groups of E(m) < 7.5 cm/s or > or = 7.5 cm/s. Patients with E(m) < 7.5 cm/s had significantly lower E/A and E(m)/A(m), and higher E/E(m) values. Multilinear regression showed a negative correlation between E(m) and glycated haemoglobin (Hb(A1c)) and duration of diabetes, a negative correlation of E(m)/A(m) with age, duration of diabetes and Hb(A1c), and a positive correlation of E/E(m) with age, duration of diabetes and use of diuretics. The E/A ratio only correlated negatively with age. It is concluded that E(m) is a reliable parameter of diastolic function, and that the tissue Doppler parameters of diastolic function are associated with diabetes compensation and diabetes duration.