Answers are grounded in this paper and cite their sources.
During August and September 1993 a laser‐induced fluorescence (LIF) instrument was used to observe OH and HO 2 as part of the Tropospheric OH Photochemistry Experiment (TOHPE) in the mountains west of Boulder, Colorado. A prototype version of this instrument has been described previously. Modifications were made to the instrument for TOHPE, including the integration of a new dye laser. The instrument was calibrated by producing known amounts of OH and HO 2 above the instrument inlet. HO 2 was measured on 19 days during TOHPE, while OH was measured on 5 days. Although poor laser performance limited the detection limit to 1 to 2×l0 6 cm −3 for an integration time of 300 s and a signal‐to‐noise ratio of 1, OH concentrations were observed to reach 3 to 7×l0 6 cm −3 near midday. HO 2 typically peaked near 1×10 8 cm −3 . HO 2 consistently reached its maximum near local noon. Observations made with the LIF instrument are compared with observations made with an ion‐assisted technique.
No takes yet. Share an insight, caveat, or question.
Mather et al. (1997) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: