Key result
Point-of-care single-lead ECG fails to increase oral anticoagulation initiation compared to usual care.
Why the study?
Despite the benefits of oral anticoagulation, many individuals with diagnosed AF do not receive it, and whether cardiac rhythm assessment impacts OAC use in patients with previously diagnosed AF was unknown.
Does point-of-care single-lead ECG rhythm assessment increase oral anticoagulation initiation in older adults with previously diagnosed atrial fibrillation?
RCT (n=4,593)
Cluster randomization at the practice level
Yes
Does point-of-care single-lead ECG rhythm assessment increase oral anticoagulation initiation in older adults with previously diagnosed atrial fibrillation?
Routine point-of-care single-lead ECG rhythm assessment does not increase overall OAC prescribing rates for previously diagnosed AF, but capturing a 'Possible AF' reading actively prompts increased initiation and decreased discontinuation of anticoagulation.
Answers are grounded in this paper and cite their sources.
Point-of-care single-lead ECG does not increase overall OAC initiation in known AF; challenges routine implementation and extends evidence on rhythm-specific prescribing influences.
Background: Despite benefits of oral anticoagulation (OAC), many individuals with diagnosed atrial fibrillation (AF) do not receive OAC. Objective: The purpose of this study was to assess whether cardiac rhythm assessment for AF impacted use of OAC in patients with previously diagnosed AF. Methods: VITAL-AF was a cluster randomized controlled trial conducted in 16 primary care practices assessing the efficacy of AF rhythm assessment with single-lead electrocardiogram in routine care. Patients 65 years and older were offered rhythm assessment at visits. In this secondary analysis, we evaluated rhythm assessment uptake and compared initiation and discontinuation of OAC in patients with previously diagnosed AF from intervention and control arms over 1 year. Results: The study included 4593 patients with previously diagnosed AF (2250 intervention; 2343 control). In the intervention arm, 2022 (89.9%) completed rhythm assessment (median 2 visits with rhythm assessment) and 40.1% had ≥1 "Possible AF" result. Initiation of OAC was similar in the intervention (17.7%) and control (19.1%) arms but was influenced by the rhythm assessment result: higher with a "Possible AF" (26.1%; adjusted odds ratio [aOR] 1.62; 95% confidence interval [CI] 1.04-2.51), and lower with a "Normal" result (9.9%; aOR 0.45; 95% CI 0.29-0.71) compared to control. OAC discontinuation was similar in the intervention (6.3%) and control (7.2%) arms, with lower discontinuation with a "Possible AF" result (3.8%; aOR 0.51; 95% CI 0.32-0.81). Conclusions: Including patients with previously diagnosed AF in a point-of-care rhythm assessment strategy did not increase overall OAC use compared to the control arm. However, the rhythm assessment result influenced both initiation and discontinuation of OAC.
No takes yet. Share an insight, caveat, or question.
Ashburner et al. (2023) conducted an RCT in Previously diagnosed atrial fibrillation (n=4,593). Single-lead electrocardiogram rhythm assessment vs. Usual care was evaluated on Initiation of oral anticoagulation (OAC) among patients not on OAC at baseline (p=0.59). Point-of-care single-lead ECG rhythm assessment did not increase overall oral anticoagulation initiation compared to usual care, though specific rhythm results influenced prescribing decisions.
Synapse has enriched 10 related papers. Consider them for comparative context: