Key result
Radiofrequency ablation with Ablation Index significantly reduced the rate of atrial arrhythmia recurrence by 65% compared to second-generation cryoballoon at 12-month follow-up (HR 0.35).
Why the study?
Due to a lack of direct comparative evidence between the latest catheter ablation technologies, there is uncertainty regarding the best treatment option for persistent AF.
Does radiofrequency ablation with Ablation Index reduce 12-month atrial arrhythmia recurrence compared to second-generation cryoballoon in patients with persistent atrial fibrillation?
Does radiofrequency ablation with Ablation Index reduce 12-month atrial arrhythmia recurrence compared to second-generation cryoballoon in patients with persistent atrial fibrillation?
Hazard Ratio: 0.35 (95% CI 0.23–0.52)
Absolute Event Rate: 18% vs 41%
Radiofrequency ablation with Ablation Index significantly reduced atrial arrhythmia recurrence at 12 months and fluoroscopy time compared to second-generation cryoballoon in patients with persistent atrial fibrillation, though with longer procedure times.
May support Ablation Index RF preference; leaves open need for randomized confirmation.
INTRODUCTION: Both radiofrequency (RF) and cryoballoon (CB) ablation are treatment options for persistent atrial fibrillation (PsAF). An important recent innovation in RF ablation is Ablation Index (AI), known also as the VISITAG SURPOINT™ Module, a composite lesion quality marker whose use has been shown to significantly reduce the incidence of acute and late pulmonary vein (PV) reconnection and the recurrence of atrial arrhythmias in PsAF. Due to a lack of direct comparative evidence between the latest generations of technologies, there is uncertainty regarding the best treatment option in PsAF. The objective of the present study was to conduct a matching-adjusted indirect treatment comparison (MAIC) using individual patient-level data (IPD) to assess the comparative effectiveness of the THERMOCOOL SMARTTOUCH™ Catheter or the THERMOCOOL SMARTTOUCH™ SF Catheter with AI/VISITAG SURPOINT™ Module (STAI) versus the second-generation CB catheter (Arctic Front Advance™; herein referred to as CB) with respect to 12-month atrial arrhythmia recurrence, fluoroscopy time, and procedural efficiency. METHODS: IPD for STAI were obtained from four investigator-initiated studies and were pooled. Comparable CB studies identified from a systematic literature review were also pooled. In the absence of a common treatment arm between STAI and CB studies, an unanchored MAIC was conducted. The primary analysis compared the pooled STAI IPD to the pooled CB cohort, with corrections for differences across trials, including eligibility criteria and patient baseline characteristics. Scenario and sensitivity analyses were conducted to assess the robustness of the primary analysis. RESULTS: In the primary analysis, which was adjusted for left atrial diameter (LAD), age, diabetes, and sex, STAI was associated with a statistically significant 65% relative reduction in the rate of arrhythmia recurrence compared to CB at 12-month follow-up (HR 0.35; 95% CI 0.23, 0.52). STAI was associated with shorter total fluoroscopy time than CB but longer procedure time. Results were consistent across scenario and sensitivity analyses. CONCLUSION: Radiofrequency ablation with AI significantly reduced atrial arrhythmia recurrence at 12-month follow-up and fluoroscopy time compared to CB, with longer procedure times.
No takes yet. Share an insight, caveat, or question.
Hussein et al. (2021) studied Persistent Atrial Fibrillation (PsAF) (n=580). Radiofrequency ablation with Ablation Index (STAI) vs. Second-generation cryoballoon (CB) was evaluated on Atrial arrhythmia recurrence at 12 months (HR 0.35, 95% CI 0.23-0.52). Radiofrequency ablation with Ablation Index significantly reduced the rate of atrial arrhythmia recurrence by 65% compared to second-generation cryoballoon at 12-month follow-up (HR 0.35).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: