The results of pressure management field studies have shown that the leakage exponent is often considerably higher than the theoretical orifice value of 0.5. The first part of this paper identifies and analyses factors that may be responsible for the higher leakage exponents. Four factors are considered: leak hydraulics, pipe material behaviour, soil hydraulics and water demand. The second part of the paper presents the results of an experimental study with different pipe materials. The pipes used were taken from the field in Johannesburg or consisted of new pipes with artificially induced failures. The leakage exponents found were in the following ranges: • Asbestos-cement pipe with longitudinal crack 0.78 – 1.04 • Steel pipe with corrosion cluster 1.90 – 2.30 • Steel and uPVC Pipe with round hole 0.52 • uPVC pipe with longitudinal crack 1.50 – 1.85 • uPVC pipe with circumferential crack 0.40 – 0.52
No takes yet. Share an insight, caveat, or question.
Greyvenstein et al. (2007) studied this question.