Answers are grounded in this paper and cite their sources.
The extremely low magnetic losses of amorphous metals motivated construction and testing of an induction motor stator using this material. A 1/3 horsepower, two-pole, 230 V, three-phase stator was built using the conventional approach of stacked laminations. Because of dimensional limitations of available material, the core was constructed with six 60°segments in each layer. Two comparison stators were made using 0.46 mm common iron and 0.36 mm M22 silicon iron core laminations.
No takes yet. Share an insight, caveat, or question.
Mischler et al. (1981) studied this question.