Key result
Smartphone-case ECG screening detects AF in ~4% of patients, identifying 36 new diagnoses.
Why the study?
Questions regarding how to screen, whom to screen, and the optimal setting for atrial fibrillation screening remain unanswered.
Is a federal cardiac monitoring system using a smartphone-case based single-lead ECG feasible and effective for detecting newly diagnosed atrial fibrillation and initiating anticoagulation in primary care patients at high cardiovascular risk in Russia?
Cohort (n=3,249)
Yes
Is a federal cardiac monitoring system using a smartphone-case based single-lead ECG feasible and effective for detecting newly diagnosed atrial fibrillation and initiating anticoagulation in primary care patients at high cardiovascular risk in Russia?
Answers are grounded in this paper and cite their sources.
Demonstrates that a centralized federal screening system using smartphone-based single-lead ECGs in primary care can rapidly diagnose previously undetected atrial fibrillation (mean 3 days) and facilitate timely anticoagulation in high-risk urban and rural patients.
Background: Screening for atrial fibrillation has the potential to significantly reduce cardiovascular morbidity and mortality. However, questions in regard to how to screen, on whom to screen, and the optimal setting of screening remain unanswered. Objective: To assess the applicability of a federal cardiac monitoring for atrial fibrillation (AF) screening and remote heart rhythm monitoring in patients at high cardiovascular risk in a mixed urban and rural population in Russia. Methods: This is a prospective multicenter cohort study including 3249 individuals with high cardiovascular risk (mean age 56 ± 12.8 years) from the larger Moscow region who were screened for AF using a smartphone-case based single-lead ECG monitor over a period of 18 month. The endpoints were considered as number of newly diagnosed AF; mean time to diagnosis; number of patients for the first time assigned to anticoagulation therapy; frequency of adverse events. Results: A trial fibrillation was diagnosed in 126 patients, 36 of them for the first time. The mean time to diagnosis was 3 ± 2 days. Of 36 patients, the CHA2DS2-VASc score was ≥1 in 34 cases, ≥2 in 29 cases. Anticoagulant therapy was first induced in 31 patients. One death in newly diagnosed group and two deaths in chronic group were registered. There were a total of eight hospitalizations: one in newly diagnosed and seven in chronic AF patients. Conclusion: Our results indicate that a Federal AF screening system in patients at high cardiovascular risk by using a smartphone-case based single lead ECG which is supported by centrally located ECG specialist and central data management is feasible and reliable when performed in a mixed urban and rural area. Further studies are needed to evaluate the full potential of this approach.
No takes yet. Share an insight, caveat, or question.
Gognieva et al. (2022) conducted a cohort in High cardiovascular risk screened for atrial fibrillation (n=3,249). Federal cardiac monitoring system using a smartphone-case based single-lead ECG (CardioQVARK) was evaluated on Number of newly diagnosed atrial fibrillation cases. Smartphone-case single-lead ECG screening detected atrial fibrillation in 126 of 3,249 patients, with 36 newly diagnosed cases and a mean time to diagnosis of 3 ± 2 days.