Key result
Transthoracic echocardiography in the prone position using a TEE probe yielded a lower mean ejection fraction compared to standard supine TTE in normal adults.
Why the study?
Transthoracic echocardiography (TTE) in the prone position is challenging, and the reproducibility and correlation of measurements using an external transesophageal echocardiography (TEE) probe compared with standard supine TTE are unknown.
Does transthoracic echocardiography in the prone position using an external TEE probe provide comparable measurements to standard supine TTE in normal adults?
Cross-Sectional (n=30)
Does transthoracic echocardiography in the prone position using an external TEE probe provide comparable measurements to standard supine TTE in normal adults?
Assessment of cardiac dimensions and systolic function in the prone position using a transthoracic TEE probe is feasible and agrees well with standard supine TTE for LV and aortic dimensions.
Answers are grounded in this paper and cite their sources.
Prone-position EF may require cautious interpretation; leaves open validation of position-specific norms in broader populations.
Background: Transthoracic echocardiography (TTE) in prone position is challenging. Innovative use of transesophageal echocardiography (TEE) probe to perform TTE for such patients was described; but reproducibility and correlation of the TTE measurements by this technique with those obtained by the standard supine TTE study are still unknown. Methods: We enrolled 30 non-COVID-19 individuals, with a mean (SD) age 35 (10.9) years and 11 females, to study the agreement between the transthoracic measurements of the left ventricular (LV), left atrial (LA) and aortic dimensions obtained in prone position using an external TEE probe versus the standard supine position using the conventional TTE probe. Results: There were no significant differences between LV end-diastolic and end-systolic diameters, septal wall thickness, posterior wall thickness and aortic root dimensions in the prone versus the supine positions. While the mean ejection fraction (EF) (60.3% vs. 63.1%, P = 0.014) and mean LA dimensions (1.8 vs. 1.9 cm/m2, P < 0.001) were significantly lower in the prone position. The mean time of scans was significantly longer in the prone as compared to the supine (12.5 vs 4.5 minutes, P < 0.001). All supine studies had good quality while in the prone position 4 studies were of poor quality, and one was non-diagnostic. Conclusions: Assessment of cardiac dimensions and systolic function in the prone position using transthoracic TEE probe was feasible. LV and aortic dimensions agreed well with the standard TTE in supine position, however, LA dimensions and EF were lower in the prone position.
No takes yet. Share an insight, caveat, or question.
Taha et al. (2020) conducted a cross-sectional in Normal adults (n=30). Transthoracic echocardiography in prone position using an external TEE probe vs. Standard supine position using conventional TTE probe was evaluated on Mean ejection fraction (EF) (p=0.014). Transthoracic echocardiography in the prone position using a TEE probe yielded a lower mean ejection fraction compared to standard supine TTE in normal adults.