October 1, 1993European Journal of Ophthalmology

Accuracy of the Potential Acuity Meter in Predicting the Visual Outcome in Cases of Cataract Associated with Macular Degeneration

View Full Paper
Ask AI
Bookmark
Share

Why the study?

Does the Potential Acuity Meter accurately predict postoperative visual acuity in patients with cataract and age-related macular degeneration?

Population

130 cases of cataract, 54 of whom had preoperatively proved or suspected age-related macular degeneration…

Comparison

Preoperative evaluation with Potential Acuity… vs Final visual acuity at 3 months postoperatively

Design

Cohort

Follow-up

3 months postoperatively

Authors

JAJ. L. AlióUniversitat de Miguel Hernández d'ElxAAA. ArtolaUniversity of AlicanteJRJosé M. Ruiz‐MorenoHospital de Nens de Barcelona

Discussion

Loading...

Member takes

Implication

Supports PAM prediction in confirmed ARMD; leaves open accuracy in doubtful cases and needs prospective validation.

Structured PICO

Does the Potential Acuity Meter accurately predict postoperative visual acuity in patients with cataract and age-related macular degeneration?

P
Population
130 cases of cataract, 54 of whom had preoperatively proved or suspected age-related macular degeneration (ARMD) associated with a cataract.
I
Intervention
Preoperative evaluation with Potential Acuity Meter (PAM) followed by extracapsular extraction and intraocular lens (IOL) implantation
C
Comparator
Final visual acuity at 3 months postoperatively (diagnostic accuracy comparison)
O
Outcome
Accuracy and specificity of PAM prediction compared to final visual acuity at 3 months postoperativelysurrogate

The Potential Acuity Meter is a reliable clinical technique for predicting visual results after cataract surgery in patients with confirmed or doubtful macular pathology.

Cite This Study

Alió et al. (1993) studied this question.

synapsesocial.com/papers/6a706b4e35aa2c282ce1bc6bhttps://doi.org/10.1177/112067219300300403
View Full Paper
Ask AI
Bookmark
Share

Also Consider

Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1SENILE MACULAR DEGENERATION: A CASE-CONTROL STUDY1983 · 591 citations
  2. 2THE FRAMINGHAM EYE STUDY1977 · 758 citations
  3. 3Cataracts and Macular Degeneration in Older Americans1982 · 276 citations
  4. 4Laser Interferometric Visual Acuity in Senile Macular Degeneration1983 · 29 citations