Key result
An oscillation-free fully staggered algorithm with a numerically consistent stabilization term was unconditionally absolutely stable for modeling cardiac electromechanics.
Why the study?
Numerical modeling of cardiac electromechanics suffers from unresolved numerical oscillations caused by the dependence of force generation models on fiber shortening velocity when using computationally preferable staggered schemes.
The proposed fully staggered algorithm successfully eliminates numerical oscillations in cardiac electromechanics modeling while maintaining computational efficiency.
Enables reliable cardiac electromechanics simulations; leaves open clinical translation pending validation.
In this paper we address an unresolved problem in the numerical modeling of cardiac electromechanics, that is the onset of numerical oscillations due to the dependence of force generation models on the fibers shortening velocity. A way to avoid numerical oscillations is to use monolithic schemes for the solution of the coupled problem of active–passive mechanics. However, staggered strategies, which foresee the sequential solution of the models of force generation and of tissue mechanics, are preferable, due to their reduced computational cost and low implementation effort. In this paper we propose a cure for this issue, by introducing, with respect to the standard staggered scheme, a numerically consistent stabilization term. This term is derived in virtue of the identification of the cause of instability in the mismatch between macroscopic and microscopic strains, inconsistently expressed in Lagrangian and Eulerian coordinates, respectively. By considering a model problem of active mechanics we prove that the proposed scheme is unconditionally absolutely stable (i.e. it is stable for any time step size), yet within a fully staggered framework. As such, the new scheme removes the non-physical oscillations, as we prove by applying it to three force generation models, namely the Niederer–Hunter–Smith model, the model by Land and coworkers, and the mean-field force generation model that we have recently proposed.
No takes yet. Share an insight, caveat, or question.
Regazzoni et al. (2020) studied this question. Oscillation-free fully staggered algorithm vs. Standard staggered scheme was evaluated on Numerical stability. An oscillation-free fully staggered algorithm with a numerically consistent stabilization term was unconditionally absolutely stable for modeling cardiac electromechanics.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: