Key result
Nonlinear arterial tube-load modeling cuts blood pressure waveform fitting error by ~30%.
Why the study?
Does a nonlinear arterial tube-load model technique accurately estimate pulse transit time as a function of blood pressure and improve cuff-less blood pressure calibration compared to linear and naïve estimation techniques?
Does a nonlinear arterial tube-load model technique accurately estimate pulse transit time as a function of blood pressure and improve cuff-less blood pressure calibration compared to linear and naïve estimation techniques?
Answers are grounded in this paper and cite their sources.
This nonlinear arterial tube-load modeling technique enables estimation of pulse transit time across the entire cardiac cycle from proximal and distal waveforms after mathematical elimination of wave reflection, offering a perturbation-less approach for cuff-less blood pressure calibration and enhanced arterial stiffness monitoring.
OBJECTIVE: pulse transit time (PTT) varies with blood pressure (BP) throughout the cardiac cycle, yet, because of wave reflection, only one PTT value at the diastolic BP level is conventionally estimated from proximal and distal BP waveforms. The objective was to establish a technique to estimate multiple PTT values at different BP levels in the cardiac cycle. METHODS: a technique was developed for estimating PTT as a function of BP (to indicate the PTT value for every BP level) from proximal and distal BP waveforms. First, a mathematical transformation from one waveform to the other is defined in terms of the parameters of a nonlinear arterial tube-load model accounting for BP-dependent arterial compliance and wave reflection. Then, the parameters are estimated by optimally fitting the waveforms to each other via the model-based transformation. Finally, PTT as a function of BP is specified by the parameters. The technique was assessed in animals and patients in several ways including the ability of its estimated PTT-BP function to serve as a subject-specific curve for calibrating PTT to BP. RESULTS: the calibration curve derived by the technique during a baseline period yielded bias and precision errors in mean BP of 5.1 ± 0.9 and 6.6 ± 1.0 mmHg, respectively, during hemodynamic interventions that varied mean BP widely. CONCLUSION: the new technique may permit, for the first time, estimation of PTT values throughout the cardiac cycle from proximal and distal waveforms. SIGNIFICANCE: the technique could potentially be applied to improve arterial stiffness monitoring and help realize cuff-less BP monitoring.
No takes yet. Share an insight, caveat, or question.
Gao et al. (2016) studied Cardiac catheterization patients (mainly hypertension, coronary artery disease, dyslipidemia, and/or diabetes); also validated in 12 healthy adult beagles (n=54). Nonlinear arterial tube-load model technique for estimating pulse transit time (PTT) as a function of blood pressure (BP) vs. Linear arterial tube-load model technique and naïve characteristic-point time-delay technique was evaluated on Bias and precision errors in mean blood pressure (MP) using baseline subject-specific calibration curves during hemodynamic interventions, and distal BP waveform fitting root-mean-squared-error (RMSE) (MD -0.5 mmHg in distal BP waveform RMSE vs linear transfer function model, p=<0.0167). The nonlinear arterial tube-load model calibrated pulse transit time to mean blood pressure with bias and precision errors of 5.1 ± 0.9 and 6.6 ± 1.0 mmHg and reduced waveform fitting RMSE by 24-35%.
Synapse has enriched 10 related papers. Consider them for comparative context: