Purpose The International Atomic Energy Agency ( IAEA ) and the American Association of Physicists in Medicine ( AAPM ) have jointly published a new code of practice (CoP), TRS 483, for the dosimetry of small static photon fields used in external beam radiotherapy. It gave recommendations on how to perform reference dosimetry in nonstandard machine‐specific reference (msr) fields and measure field output factors in small fields. The purpose of this work was to perform a dosimetric evaluation of the recommendations given in this CoP. Methods All measurements were done in a Varian TrueBeam™ ST x linear accelerator. Five ionization chambers were used for beam quality measurements, four Farmer type ionization chambers for performing reference dosimetry and two diodes for performing field output factor measurements. Field output factor measurements were done for fourteen field sizes (ranging from 0.5 cm × 0.5 cm to 10 cm × 10 cm). Beam energies used were: 6 MV WFF , 6 MV FFF , 10 MV WFF , and 10 MV FFF . Where appropriate, results from this study were compared with those obtained from the recommendations given in the IAEA TRS 398 CoP, AAPM TG 51 and TG 51 Addendum protocols. Results Beam quality measurements show that for all beam energies and for equivalent square msr field sizes ranging from 4 cm × 4 cm to 10 cm × 10 cm, agreement between calculated and measured values of TPR 20,10 (10) was within 0.6%. When % dd (10,10) X was used as beam quality specifier, the agreement was found to be within 0.8%. Absorbed dose to water per unit monitor unit at the depth of maximum dose z max in a beam of quality Q, / MU , was determined using both % dd (10,10) X and TPR 20,10 (10) as beam quality specifiers. Measured ratios of D w , Q ( z max )/MU, determined using the two approaches, ranged between 0.999 and 1.000 for all the beam energies investigated. Comparison with TRS 398, TG 51 and TG 51 addendum protocols show that depending on beam energy, the mean values of the ratios TRS 398/ TRS 483, TG 51/ TRS 483, and TG 51 Addendum/ TRS 483 of D w , Q ( z max )/ MU determined using both approaches show excellent agreement with TRS 398 CoP (to within 0.05%); agreement with TG 51 and TG 51 addendum was to within 0.3% for all four beam energies investigated. Field output factors, determined using the two methods recommended in the TRS 483 CoP, showed excellent agreement between the two methods. For the 1 cm collimator field size, the mean value of the field output factor obtained from an average of the two detectors investigated was found to be 2% lower than the mean value of the uncorrected ratio of readings. Conclusion For beams with and without flattening filters, the values of D w , Q ( z max )/MU obtained following the new CoP are found to be consistent with those obtained using TRS 398, TG 51 and TG 51 addendum protocols to within 0.3%. Field output factors for small beams can be improved when the correction factors for different detectors included in TRS 483 are appropriately incorporated into their dosimetry.
No takes yet. Share an insight, caveat, or question.
Huq et al. (2018) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: