Answers are grounded in this paper and cite their sources.
Background Preimplantation genetic testing for aneuploidy (PGT-A) can improve embryo selection in assisted reproductive technology; however, the trophectoderm (TE) biopsy required for testing is invasive and may compromise embryo integrity. While noninvasive chromosomal screening (NICS) using cell-free DNA from spent embryo culture medium (SECM) is a promising alternative, its research in frozen–thawed embryos remains limited. We systematically evaluated and compared the detection performance of SECM-based NICS in fresh and frozen–thawed embryos and explored its clinical application potential. Overall, 104 SECM samples from 27 couples who were undergoing intracytoplasmic sperm injection–PGT-A were analyzed (65 from the fresh group and 39 from the frozen–thawed group). TE biopsy results were used as the gold standard for assessing NICS efficacy. A paired-sample design was employed to conduct synchronous sequencing analyses of TE biopsy cells, fresh SECM, frozen–thawed SECM, and whole-embryo samples from 24 embryos. Results The overall detection success rate of the NICS was 98.08%. When TE biopsy was used as the gold standard, the overall sensitivity, specificity, and clinical consistency of the NICS were 88.46%, 50%, and 79.41%, respectively. Stratified analysis showed that, for SECM-NICS, frozen–thawed embryos demonstrated higher DNA library concentrations ( P = 0.046), sensitivity (97.30% vs 78.05%, P = 0.008), positive predictive value (PPV; 100% vs 72.73%, P < 0.01), and clinical consistency (97.37% vs 68.75%, P = 0.001), with a lower rate of complete chromosomal inconsistency (2.63% vs 35.94%, P < 0.01), compared with fresh embryos. The high-concentration group (≥10 ng/µL) exhibited superior PPV and clinical consistency. Paired-sample analysis confirmed a high consistency between the TE biopsy and whole-embryo analysis results (clinical consistency: 100%). When whole-embryo sequencing was used as the absolute gold standard, the frozen–thawed SECM group showed a significantly lower rate of complete chromosomal inconsistency than the fresh group (4.35% vs 33.33%, P = 0.023). Mosaics were a key contributor to diagnostic discordance. Conclusion The detection performance of NICS based on frozen–thawed SECM demonstrated superior sensitivity, PPV, and consistency with the actual chromosomal status compared with that using fresh embryos; this approach, as a noninvasive method, demonstrates potential for genetic assessment of cryopreserved embryos, potentially avoiding the need for secondary, invasive biopsies.
No takes yet. Share an insight, caveat, or question.
Wen et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: