Key result
A coronary sinus-guided right anterior oblique projection significantly reduced the degree of triangle of Koch image shortening to 0.83% compared to 13.03% for RAO30° and 3.93% for RAO45°.
Why the study?
Variability in the anatomy and orientation of the triangle of Koch complicates ablation procedures involving the atrioventricular node.
Does a coronary sinus-guided RAO projection reduce image shortening of the triangle of Koch compared to standard RAO projections in patients undergoing ablation?
Observational (n=104)
No
Does a coronary sinus-guided RAO projection reduce image shortening of the triangle of Koch compared to standard RAO projections in patients undergoing ablation?
A coronary sinus-guided RAO projection reliably tracks the orientation of the triangle of Koch and minimizes image shortening during ablation procedures compared to standard RAO projections.
Answers are grounded in this paper and cite their sources.
May improve Koch triangle visualization in EP labs; leaves open whether it affects procedural safety or success.
Background Variability in the anatomy and orientation of the triangle of Koch (TK) complicates ablation procedures involving the atrioventricular (AV) node. We used CT angiography (CTA) to assess the anatomical TK orientation, the CS ostium direction, and the relationship between the two, and we validated an individualized CS-guided projection during ablation procedures. Methods In 104 patients without structural heart disease undergoing computed tomography (CT) angiography, TK orientations were determined in relation to the coronary sinus ostium (CSo) as well as two standard right anterior oblique (RAO) projection angles (30 o and 45 o ) commonly used in ablation procedures. Results A CS-guided RAO projection (RAOCS) was shown to best track the orientation of the TK compared to RAO30° and 45°, with TK orientation strongly correlating with the CSo direction ( r = 0.86, P < 0.001). In addition, the mean relative difference between the angle of the CSo and TK orientation was 5.54 ± 0.48°, consistent with a reduction in the degree of image shortening compared to traditional RAOs. Moreover, in vivo validation following ablation revealed that using a CS-guided projection limited the degree of on-screen image shortening compared to both the RAO30° and 45° in 25 patients with catheter ablation procedures. Conclusion In hearts with a normal structure, the CSo direction offers a reliable predictor of the TK orientation which can be used to guide the projection of the TK during ablation procedures.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2020) conducted an observational in Structurally normal hearts (n=104). Coronary sinus-guided right anterior oblique projection (RAOCS) vs. Standard RAO30° and RAO45° projections was evaluated on Rate of Triangle of Koch image shortening (p=<0.05). A coronary sinus-guided right anterior oblique projection significantly reduced the degree of triangle of Koch image shortening to 0.83% compared to 13.03% for RAO30° and 3.93% for RAO45°.
Synapse has enriched 10 related papers. Consider them for comparative context: