Why the study?
Does venous angiography with cineradiography provide useful diagnostic information for evaluating pericardial disease?
Does venous angiography with cineradiography provide useful diagnostic information for evaluating pericardial disease?
Venous angiography with cineradiography is a quick, simple, and inexpensive technique that may provide valuable dynamic information for diagnosing pericardial disease.
Answers are grounded in this paper and cite their sources.
Cineradiography may aid pericardial evaluation; leaves open its role versus modern imaging in prospective studies.
This report describes a modification of the method of venous angiography for the evaluation of pericardial disease, with cineradiography. The use of venous angiography with a rapid serial film-changer for diagnosis of pericardial effusion was described by Williams and Steinberg in 1949 (1). Paul et al. introduced the use of carbon dioxide angiography in man in 1957, offering an alternative and very safe technic (2). The technic to be described herein is quick, simple, and inexpensive. Analysis of our material suggests that the sense of motion imparted by cineradiography may give information about the underlying gross pathology, which is less readily apparent on large serial films. Materials and Method This study is based on the examination of 26 patients suspected clinically of having pericardial effusions, and an additional 3 patients with clinical evidence of pericardial constriction. Nine patients without evidence of pericardial or cardiac disease are included as normal controls. A sharply bevelled 2 1∕2-inch metal needle with a 15-gauge Teflon sleeve (Rochester needle) is placed in an antecubital vein (usually the right). This can be inserted with a minimum of discomfort without need for local anesthesia. The inner metal needle is withdrawn and the Teflon cannula advanced to its hub. Once the needle is withdrawn, it cannot be reinserted. Satisfactory placement eliminates the possibility of extravasation of contrast medium. The injections are made by hand, using a glass and metal syringe with a flat hand plunger. Ditriokon-70, 35 to 40 cc, is used as the triiodobenzoic acid derivative contrast agent. The patient is usually recumbent, though an orthopneic patient can be examined in a semierect position. The examinations are performed with a remote control 16 mm cinefluoroscopic unit with a 9-inch image intensifier and automatic brightness control. After preliminary fluoroscopy, a field is selected to include the right border of the heart. The opacified right atrium is recorded on the cine film and can also be observed on the television monitor. If the field does not include the left side of the heart, the screen can be moved to the left when the contrast medium bolus leaves the right heart chambers. The actual study usually takes about five minutes to perform. To permit measurement of the width of the right atrial border from the projected image, correction is made for magnification. This is done by placing a tape with lead markers at 1 cm intervals both on the table top and on the front of the patient's chest, and recording them on the cine film strip. From the projected image, the true measurement can then be taken arbitrarily at the midplane of the chest. This measurement is made during atrial diastole in each case.
No takes yet. Share an insight, caveat, or question.
Dinsmore et al. (1966) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: