The particle release from cold-rolled niobium surfaces under 14-MeV-neutron impact to a total dose of 4.6 ×{} 10¹⁵ neutrons/cm² was investigated under ultrahigh-vacuum conditions and at ambient temperature. The type and amount of material released and deposited on a substrate surface was determined independently by four analytical techniques. Surprisingly, there were two types of deposits---one in the form of large chunks, the other a more even layer covering the surface. The chunk emission cannot be explained by existing neutron-sputtering theories.
No takes yet. Share an insight, caveat, or question.
Kaminsky et al. (1974) studied this question.