Describes a simple distal coronary perfusion technique using an intra-coronary shunt tube to maintain temporary perfusion during off-pump coronary artery bypass grafting.
Answers are grounded in this paper and cite their sources.
May support distal perfusion adjunct in OPCAB; hypothesis-generating and requires prospective validation before adoption.
This communication describes the surgical technique and clinical outcomes of a simple coronary perfusion technique for use during off-pump coronary artery bypass grafting. An intra-coronary shunt tube connected to the graft conduit (saphenous vein or radial artery) with an arterial blood source (ascending aorta or right internal thoracic artery) was inserted distally via a coronary arteriotomy for temporary perfusion of six left anterior descending arteries and two right coronary arteries.
No takes yet. Share an insight, caveat, or question.
T. Ohtsuka (2002) studied this question.