This paper proposes a method to reduce the steadystate oscillation and to mitigate the probability of losing the tracking direction of the perturb and observed (P&O)-based maximum power point tracking (MPPT) for PV system. The modified scheme retains the conventional P&O structure, but with a unique technique to dynamically alter the perturbation size. At the same time, a dynamic boundary condition is introduced to ensure that the algorithm will not diverge from its tracking locus. The modified P&O is simulated in MATLAB Simulink and its performance is benchmarked using the standard MPPT efficiency ηM P P T calculation. Furthermore, the proposed concept is validated experimentally using a buck-boost converter, fed by a solar PV array simulator (PVAS). Based on the EN 50530 dynamic irradiance tests, the proposed method achieved an average ηMP P T almost 1.1% higher than the conventional P&O when irradiance changes slowly and about 12% higher under fast change of irradiance.
No takes yet. Share an insight, caveat, or question.
Ahmed et al. (2016) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: