Why the study?
Does a mobile GPU-based parallel automatic ECG analysis algorithm reduce processing time and energy consumption compared to a sequential CPU algorithm for long-term ECG data?
Does a mobile GPU-based parallel automatic ECG analysis algorithm reduce processing time and energy consumption compared to a sequential CPU algorithm for long-term ECG data?
A mobile GPU-based parallel ECG analysis algorithm significantly reduces processing time and energy consumption for long-term ECG data on mobile devices without compromising classification accuracy.
Answers are grounded in this paper and cite their sources.
Mobile GPU acceleration enables rapid on-device long-term ECG analysis; leaves open prospective validation for arrhythmia detection in clinical workflows.
BACKGROUND: Long-term electrocardiogram (ECG) is one of the important diagnostic assistant approaches in capturing intermittent cardiac arrhythmias. Combination of miniaturized wearable holters and healthcare platforms enable people to have their cardiac condition monitored at home. The high computational burden created by concurrent processing of numerous holter data poses a serious challenge to the healthcare platform. An alternative solution is to shift the analysis tasks from healthcare platforms to the mobile computing devices. However, long-term ECG data processing is quite time consuming due to the limited computation power of the mobile central unit processor (CPU). METHODS: This paper aimed to propose a novel parallel automatic ECG analysis algorithm which exploited the mobile graphics processing unit (GPU) to reduce the response time for processing long-term ECG data. By studying the architecture of the sequential automatic ECG analysis algorithm, we parallelized the time-consuming parts and reorganized the entire pipeline in the parallel algorithm to fully utilize the heterogeneous computing resources of CPU and GPU. RESULTS: The experimental results showed that the average executing time of the proposed algorithm on a clinical long-term ECG dataset (duration 23.0 ± 1.0 h per signal) is 1.215 ± 0.140 s, which achieved an average speedup of 5.81 ± 0.39× without compromising analysis accuracy, comparing with the sequential algorithm. Meanwhile, the battery energy consumption of the automatic ECG analysis algorithm was reduced by 64.16%. Excluding energy consumption from data loading, 79.44% of the energy consumption could be saved, which alleviated the problem of limited battery working hours for mobile devices. CONCLUSION: The reduction of response time and battery energy consumption in ECG analysis not only bring better quality of experience to holter users, but also make it possible to use mobile devices as ECG terminals for healthcare professions such as physicians and health advisers, enabling them to inspect patient ECG recordings onsite efficiently without the need of a high-quality wide-area network environment.
No takes yet. Share an insight, caveat, or question.
Fan et al. (2018) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: