Why the study?
To evaluate whether automated vorticity mapping 4D flow MRI can identify regions of quantitative flow inconsistency.
Does automated vorticity mapping on 4D flow MRI identify regions of quantitative flow inconsistency in patients undergoing MR angiography?
Does automated vorticity mapping on 4D flow MRI identify regions of quantitative flow inconsistency in patients undergoing MR angiography?
Automated vorticity mapping on 4D flow MRI can identify regions of high flow inconsistency, suggesting its utility in guiding the optimal location for accurate blood flow quantification.
May identify flow inconsistencies in aortic disease; leaves open clinical utility pending prospective validation.
Purpose To evaluate whether automated vorticity mapping four-dimensional (4D) flow MRI can identify regions of quantitative flow inconsistency. Materials and Methods In this retrospective study, 35 consecutive patients who underwent MR angiography with 4D flow MRI at 3.0 T from December 2017 to October 2018 were analyzed using a λ2-based technique for vorticity visualization and quantification. The patients were aged 58.6 years ± 14.4 (standard deviation), 12 were women, 18 had ascending aortic aneurysms (maximal diameter > 4.0 cm), and 10 had bicuspid aortic valves. Flow measurements were made in the ascending aorta (aAo), mid-descending aorta, main pulmonary artery, and superior vena cava. Statistical tests included t tests and F tests with a type I error threshold (α) of .05. Results The 35 patients were visually classified as having no (n = 9), mild (n = 8), moderate (n = 11), or severe vorticity (n = 7). Across all patients, standard deviation of cardiac output in the aAo (0.58 L/min ± 0.45) was significantly (P < .001) higher than in the pulmonary arteries (0.15 L/min ± 0.10) and descending aorta and superior vena cava (0.14 L/min ± 0.12). The standard deviation of cardiac output observed in the aAo was significantly greater (P < .01) in patients with moderate or severe vorticity (0.73 L/min ± 0.55) than in those with none or mild vorticity (0.44 L/min ± 0.26). Conclusion Cardiac output and blood flow are essential MRI measurements in the evaluation of structural heart disease. Vorticity visualization may be used to help guide optimal location for flow quantification.
No takes yet. Share an insight, caveat, or question.
Contijoch et al. (2020) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: