Answers are grounded in this paper and cite their sources.
Objective To compare the conventional method for cannulation of the internal jugular vein with the ultrasound-aided technique. Design Prospective, randomized trial. Setting Medical and surgical patients requiring central cannulation in a university hospital. Patients Consecutive medical and surgical patients in whom central venous cannulation was indicated. Interventions Cannulation of the internal jugular vein was performed by one anesthesiologist. During the first 6 months, the ultrasound-aided technique (n = 29) was used, and during the second 6 months, the conventional technique (n = 27) was applied. Measurements and main results The venous lumen was reached with fewer punctures (1.2 +/- 0.5 vs. 3.3 +/- 3.0 punctures per patient) and the cannulation time was shorter (35 +/- 19 vs. 198 +/- 211 secs) while using the ultrasound-aided technique. The ultrasound-aided method showed that the large-bore (diameter greater than 2.0 mm) needles invariably perforated the medial wall of the internal jugular vein, increasing the risk of perforating the adjacent carotid artery. Conclusions Ultrasound guidance reduces both the duration of time and the number of punctures required to cannulate the internal jugular vein. The Seldinger technique appears safer for catheterization of the internal jugular vein.
No takes yet. Share an insight, caveat, or question.
Koski et al. (1992) studied this question.